products

Dry Micro Chemiluminescence Immunoassay Analyzer

Home Products POCT

Dry Micro Chemiluminescence Immunoassay Analyzer

Dry Micro Chemiluminescence Immunoassay Analyzer
  • No Cold Chain Required: lyophilized reagents, easy transportation and storage without compromising the reagents integrity.
  • High Sensitivity: Equipped with advanced detection technology, offers exceptional sensitivity, allowing for the accurate measurement.
  • Rapid Results: First sample can be processed in just 3 minutes. 
  • Fast and Accurate: Results that are both rapid and precise.
  • Brand:

    Poclight
  • Order(MOQ):

    1
  • Payment:

    FOB, EXW
  • Product Origin:

    Nanjing, China
  • Shipping Port:

    Shanghai,Shenzhen,Guangzhou
  • Lead Time:

    10-20days
  • Weight:

    6kg
Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Micro Dry Homogeneous Chemiluminescence Immunoassay Analyzer

Based on Chemiluminescence Resonance Energy Transfer (CRET) principle, Dry Micro Chemiluminescence Immunoassay Analyzer "rapid, accurate, compact and cost-effective". 

     Specification

     Dry Homogeneous Chemiluminescence Immunoassay Analyzer

     Principle
     CRET Homogeneous CLIA
     Sample Type
     Whole blood/Serum/Plasma/etc
     Printer
     Built-in/external printer
     Dimensions
     325×231×213mm
     Communication
     LIS/HIS/5G transmission

 

POCT CLIA Analyzer

Chemiluminescence Resonance Energy Transfer (CRET) Principle

  • Overview of CRET
    • An advanced principle where energy transfer occurs between donor and acceptor molecules during the chemiluminescence process.

CRET technology principle

  • Advantages of CRET-Based Systems
    • Higher sensitivity and specificity.
    • Faster reaction times.
    • Reduced background noise leading to more accurate results.

Operation instruction for C5000

Detection Method:

  • CLIA: Uses chemiluminescent labels that produce light through a chemical reaction, which is then measured.

Sensitivity:

  • CLIA: High sensitivity, often higher than other immunoassay methods, making it suitable for detecting low concentrations of analytes.

Specificity:

  • CLIA: High specificity, reducing the likelihood of cross-reactivity and false positives.

Speed:

  • CLIA: Rapid results due to the efficient nature of chemiluminescent reactions.

Sample Volume:

  • CLIA: Requires a small sample volume, which is beneficial for tests where sample availability is limited.

Throughput:

  • CLIA: High throughput capabilities, making it suitable for high-volume testing environments like large laboratories and hospitals.

Reagent Stability:

  • CLIA: Reagents are generally stable and have a long shelf life, which is advantageous for inventory management.

Cost:

  • CLIA: Generally more cheaper than other chemiluminescence immunoassays due to the complexity of the reagents and instrumentation required.

Applications:

  • CLIA: Widely used for a broad range of applications including hormone levels, infectious diseases, tumor markers, and other clinical diagnostics.

 

 

 

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Related Products

Micro Dry Chemiluminescence Immunoassay Analyzer
New products Dry Chemiluminescence Immunoassay Analyzer

1. Reliable calibration and quality control system2. Carry-over prevention3. Maintenance-free, no liquid path inside4. No extra consumables5. Compact instrument design6. Simple operation7. No hidden cost

Details
Estradiol (E2) Test Kit (Homogeneous Chemiluminescence Immunoassay)
Estradiol (E2) Test Kit (Homogeneous Chemiluminescence Immunoassay)

This assay is intended for in vitro quantitative determination of Estradiol in human serum and plasma. The test kit is used as an aid in the evaluation of ovarian disease. For in vitro diagnostic use only. Shelf life: ● 18 months Storage: ● 2 - 30℃, away from sunlight * No cold chain

Details
cheapest handheld POCT Analyzer TSH test kit
Canine Thyroid-Stimulating Hormone (cTSH) Test Kit (Homogeneous Chemiluminescence Immunoassay)

【Technology highlight】 Chemiluminescence Reasonance Energy Transfer (CRET) Principle  【Main Components】 20 Lyophilization sphere reagents 【Caution】 • The procedure steps should be performed successively without any interruptions.  • For more information, see HSCL-5000 operator’s manual.

Details
vet POCT Analyzer VD test
canine and feline 25-hydroxy Vitamin D (A-VD) Test Kit

【Technology highlight】 Chemiluminescence Reasonance Energy Transfer (CRET) Principle   【Main Components】 20 Lyophilization sphere reagents   【Caution】 • The procedure steps should be performed successively without any interruptions.  • For more information, see C5000 operator’s manual.

Details
Chemiluminescence Immunoassay Analyzer C5000
Original Factory Dry Chemiluminescence Immunoassay Analyzer

Micro Dry Homogeneous Chemiluminescence Immunoassay Analyzer  1.High Sensitivity 2.Fast and Accurate 3.Stabel and Reliable 4.Easy to operation

Details
Peerless Automatic Chemiluminescence Immunoassay System
Professional Automated Chemiluminescence Immunoassay System Analyzer

Micro Dry Homogeneous Chemiluminescence Immunoassay Analyzer  1.High Sensitivity 2.Fast and Accurate 3.Stabel and Reliable 4.Easy to operation

Details
Myoglobin Rapid Test Kit
Myoglobin (Myo) Test Kit (Homogeneous Chemiluminescence Immunoassay)

This assay is intended for in vitro the quantitative determination of Myo  in human serum and plasma. The test kit is used as an aid in the diagnosis of acute myocardial infarction (AMI). For in vitro diagnostic use only.   Shelf life: ● 18 months Storage: ● 2 - 30℃, away from sunlight   * No cold chain

Details
vet POCT Analyzer cCRP fast test kits
Canine C-Reactive Protein (cCRP) Test Kit

【Intended Use】 POCTVET Canine C-reactive protein (cCRP) Test Kit is an in vitro veterinary diagnostic test for the quantitative determination of Canine CRP (cCRP) in serum or plasma.   【Main Components】 20 Lyophilization sphere reagents   【Storage Conditions and Expiration Date】 Veterinary C-reactive protein (cCRP) Test Kit should be stored at 2-8°C protected from light stable for 18 months. Reagents should be used immediately after opening.

Details

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.
Submit

Home

Products

WhatsApp

contact